OEM Diaphragm Liquid Pumps

KNF Neuberger
KNF transfer pumps combine maximum performance with minimum size. Chemical-resistant materials enable the pumps to convey almost any type of liquid, whether neutral or corrosive.

Learn more

Dosing/Metering

Showing 48 of 48 products in this category

No.

View

Model

Flow rate at atm. pressure l/min

Pressure bar g

Suction height, self-priming mWg

Suction height, self-priming mWg

Nominal stroke volume μl

FEM 1.02.55 RC

FEM 1.02.55 RC

0.0002 – 0.02
l/min

--
bar g

60
mWg

4
mWg

5 – 180
µl

FEM 1.02

FEM 1.02

0.0002 – 0.02
l/min

--
bar g

60
mWg

4
mWg

180
µl

FEM 1.09.55 RC

FEM 1.09.55 RC

0.0009 – 0.09
l/min

--
bar g

60
mWg

4
mWg

10 – 500
µl

FEM 1.09

FEM 1.09

0.0009 – 0.09
l/min

--
bar g

60
mWg

4
mWg

500
μl

FMM 20

FMM 20

0.018
l/min

--
bar g

10
mWg

3
mWg

8 – 17
μl

FMM 80

FMM 80

0.048
l/min

--
bar g

10
mWg

4
mWg

30 – 80
μl

NFB 25

NFB 25

2 × 0.05–0.3
l/min

--
bar g

10
mWg

3
mWg

--

NFB 5

NFB 5

2 × 0.05–0.5
l/min

--
bar g

10
mWg

3
mWg

--

NF 5

NF 5

0.05
l/min

--
bar g

10
mWg

3.5
mWg

--

NF 1.5

NF 1.5

0.06
l/min

--
bar g

60
mWg

3
mWg

--

FD 1.200

FD 1.200

Up to 0.065
l/min

--
bar g

60
mWg

4.5
mWg

50 – 200
μl

FP 7

FP 7

Up to 0.07
l/min

--
bar g

10
mWg

2
mWg

--

FP 1.7

FP 1.7

Up to 0.07
l/min

--
bar g

60
mWg

≥ 2.0
mWg

--

FL 10

FL 10

0.1
l/min

--
bar g

10
mWg

1.5 – 2
mWg

--

NF 1.10

NF 1.10

Up to 0.14
l/min

--
bar g

60
mWg

3
mWg

--

FF 12

FF 12

0.15
l/min

--
bar g

10
mWg

3
mWg

--

FF 1.12

FF 1.12

0.15
l/min

--
bar g

60
mWg

3
mWg

--

NF 1.30

NF 1.30

0.17
l/min

--
bar g

60
mWg

5
mWg

--

FF 20

FF 20

0.23
l/min

--
bar g

30
mWg

3.5
mWg

--

FP 25

FP 25

0.25
l/min

--
bar g

10
mWg

≥ 3.0
mWg

--

NF 25

NF 25

0.25
l/min

--
bar g

10
mWg

3
mWg

--

FP 1.25

FP 1.25

0.25
l/min

--
bar g

60
mWg

3
mWg

--

NF 30

NF 30

0.3
l/min

--
bar g

10
mWg

6
mWg

--

NF 1.25

NF 1.25

0.3
l/min

--
bar g

60
mWg

3
mWg

--

NF 2.35

NF 2.35

0.35
l/min

--
bar g

160
mWg

3
mWg

--

FM 50

FM 50

0.5
l/min

--
bar g

10
mWg

≥ 3.0
mWg

--

NF 60

NF 60

0.6
l/min

--
bar g

10
mWg

3
mWg

--

FMS-FC 1.70

FMS-FC 1.70

Up to 0.6
l/min

--
bar g

40
mWg

3
mWg

--

NF 1.60

NF 1.60

0.65
l/min

--
bar g

60
mWg

3
mWg

--

FP 1.70

FP 1.70

0.8
l/min

--
bar g

60
mWg

3
mWg

--

FP 70

FP 70

Up to 0.85
l/min

--
bar g

20
mWg

≥ 3
mWg

--

FP 1.150

FP 1.150

Up to 1.1
l/min

--
bar g

60
mWg

2.3
mWg

--

NF 100

NF 100

1.2
l/min

--
bar g

10
mWg

3
mWg

--

NF 1.100 EX

NF 1.100 EX

1.2
l/min

--
bar g

40
mWg

2.5
mWg

--

FP 2.150

FP 2.150

Up to 1.3
l/min

Up to 10
bar g

2.7
mWg

--

--

NF 1.100

NF 1.100

1.3
l/min

--
bar g

60
mWg

3
mWg

--

FP 150

FP 150

Up to 1.5
l/min

--
bar g

20
mWg

2.7
mWg

--

NFB 100

NFB 100

2 × 1.3
l/min

--
bar g

10
mWg

3
mWg

--

NFB 60

NFB 60

2 × 0.6
l/min

--
bar g

10
mWg

3
mWg

--

NFB 30

NFB 30

2 × 0.3
l/min

--
bar g

10
mWg

6
mWg

--

NF 300

NF 300

3.0
l/min

--
bar g

10
mWg

3
mWg

--

NF 1.300 EX

NF 1.300 EX

3.0
l/min

--
bar g

40
mWg

2.5
mWg

--

NF 1.300

NF 1.300

3
l/min

--
bar g

60
mWg

3
mWg

--

FMS-FC 1.400

FMS-FC 1.400

Up to 3.4
l/min

--
bar g

60
mWg

3
mWg

--

FP 1.400

FP 1.400

Up to 4.4
l/min

--
bar g

60
mWg

3
mWg

--

FP 400

FP 400

Up to 4.6
l/min

--
bar g

10
mWg

3
mWg

--

FK 1100

FK 1100

Up to 12.4
l/min

--
bar g

10
mWg

4.5
mWg

--

FK 1.1100

FK 1.1100

Up to 12.4
l/min

--
bar g

60
mWg

4.5
mWg

--

Note: Images are not to scale; for size comparison, please refer to the technical specifications or the actual product dimensions

    OEM Diaphragm Liquid Pumps Pump Selection FAQs

    How should a liquid pump be selected based on flow rate, pressure, and media?

    Selecting an OEM liquid pump requires assessment of liquid properties, wetted materials, pulsation, and control methods, as well as flow rate and operating pressure:

    Flow rate and transfer method: Is continuous transfer, circulation, or a specified volume per dispense required? Does the flow rate need to be adjustable?

    Pressure and suction conditions: Confirm outlet back pressure, suction height, and pressure losses across tubing, filters, and valves. Maximum flow rate and maximum operating pressure may not be achievable simultaneously; check each model’s performance curve.

    Liquid properties: Specify composition, concentration, viscosity, temperature, particle content, and sensitivity to shear.

    Pulsation requirements: For smooth transfer or applications sensitive to pressure fluctuations, vibration, or noise, consider KNF Smooth Flow low pulsation liquid pumps.

    Equipment integration: Confirm installation space, power supply, control signals, and operating cycles before selecting motor and connection configurations.

    Provide the media, required flow rate, and operating conditions wherever possible, and contact us to assess suitable models or customization. For a specified volume per dispense, see KNF OEM Dosing Pumps.

    How does KNF Smooth Flow Technology give liquid diaphragm pumps low pulsation comparable to gear pumps?

    Gear pumps transfer liquid continuously using rotating gears and typically provide smooth, low pulsation flow. Conventional liquid diaphragm pumps alternate suction and discharge, producing periodic flow and pressure pulsation.

    KNF Smooth Flow liquid pumps use 5 Diaphragm Technology or integrated pulsation dampers, depending on the model. 5 Diaphragm Technology operates five diaphragms with a one-fifth-cycle phase shift to smooth the combined flow. Integrated dampers temporarily store liquid during discharge and release it during suction to reduce interruptions and flow fluctuations These approaches enable diaphragm pumps to provide low pulsation transfer comparable to gear pumps.

    The series also retains the low-shear characteristics of diaphragm pumps. Liquid does not pass through meshing rotating gears, making the pumps suitable for shear-sensitive media. Applications involving inks or reagents can combine smooth flow with gentle transfer, while retaining self-priming, dry-running capability, and a choice of wetted materials.

    Why should cavitation be considered when transferring inks or other sensitive liquids?

    Vapor bubbles may form when local liquid pressure falls below the liquid’s vapor pressure. Their subsequent collapse can cause noise, vibration, and damage to pump components or the transferred media. Cavitation may also affect the quality of inks and other sensitive liquids.

    KNF Smooth Flow liquid pumps help reduce cavitation risk through reduced pulsation and optimized flow paths. Equipment design should also minimize inlet pressure losses by shortening suction lines, selecting suitable tubing diameters, and reducing unnecessary bends and narrow fittings.

    How should KNF liquid pump materials be selected for corrosive liquids?

    Chemical resistance depends on the full combination of wetted materials. Provide the known liquid composition, concentration, temperature, and operating conditions, and verify compatibility with the wetted materials, including compatibility with cleaning agents. This helps reduce swelling, corrosion, leakage, and media contamination.

    The KNF Modular System offers multiple material configurations for selecting suitable pump heads, diaphragms, valves, and other wetted components. If information is incomplete or compatibility is uncertain, provide the liquid name, product information, or Safety Data Sheet (SDS), and contact us to assess material combinations and customized configurations.

    Why is tubing information recommended when selecting a KNF liquid pump?

    Actual liquid pump performance is affected by tubing material, inner diameter, length, wall thickness, and elasticity. The interaction between tubing elasticity and pump pulsation can change pressure fluctuations and transfer performance within the system.

    In addition to flow rate and pressure, provide inlet and outlet tubing layouts, reservoir position, and filter and valve details. For pulsation-sensitive equipment, consider KNF Smooth Flow to reduce the effect of pump pulsation on the tubing system.

    Back to Products Contact Us

    Contact Us Top

    Selected Models

    KNF Customization · MOQ 1