Liquid Sampling Pumps

Learn more

Note: Images are not to scale; for size comparison, please refer to the technical specifications or the actual product dimensions

Liquid Sampling Pumps Pump Selection FAQs

What features do KNF liquid sampling pumps offer?

KNF offers a wide range of liquid diaphragm pumps for water quality monitoring, wastewater monitoring, environmental testing, and medical diagnostic equipment. Self-priming capability, dry-running safety, and extensive customization support different sampling processes and OEM integration requirements:

  • Self-priming and dry-run safe: Establish suction without pre-filling and accommodate brief periods without liquid during sampling.
  • Wetted material options: Different pump head, diaphragm, and valve material combinations allow assessment of chemical compatibility with sample composition and concentration.
  • Low pulsation options: For applications requiring smooth sample delivery, consider the KNF Smooth Flow series to reduce flow and pressure fluctuations during transfer.
  • Modular customization: The KNF Modular System allows materials, motors, and connections to be adapted, with MOQ = 1 for customization of even a single pump. Models supporting KNF Digital Customization allow further motor parameter adjustment for more precise customization.

Confirm target flow, sample volume per cycle, suction conditions, outlet back pressure, and cleaning requirements, then select according to sample properties and the actual sampling process.

Must the sample liquid pass through the pump?

No. In addition to direct transfer with a liquid pump, vacuum-over-liquid transfer can be used: a vacuum pump evacuates the collection vessel, and the resulting pressure difference draws the sample into it.

This avoids direct passage of sample liquid through the pump and may suit systems that seek to minimize sample-pump contact or handle liquids containing particles or fibers. Overflow protection is still required, and the effects of water vapor, aerosols, and condensate on the vacuum pump must be assessed. For volatile samples, check operating temperature and vacuum to avoid boiling caused by reduced pressure.

Vacuum-over-liquid transfer also requires valves and a vacuum vessel, generally resulting in a larger system that is more sensitive to temperature changes. Tubing pressure losses limit the aspiration distance. The vacuum pump must be able to start against vacuum in an already evacuated system.

Which KNF technologies reduce diaphragm pump pulsation during liquid sampling?

Diaphragm reciprocation causes periodic changes in liquid flow. Resistance from tubing, screens, and filters can convert flow pulsation into pressure fluctuations. If the sampling system needs smooth delivery or uses a flow sensor, consider KNF Smooth Flow Low Pulsation Pumps.

This newly-invented technology reduces pulsation using integrated damper elements or multiple diaphragms operating with phase shifts. The structure varies by model; select according to the required flow and the equipment's pulsation limits. Please contact us for details.

Can liquids containing particles or fibers be pumped directly?

Assessment is required first. Long fibers can cause blockages, while abrasive particles can wear internal components. Flow rate alone is insufficient to establish suitability. If direct passage through the pump is unsuitable, compare two indirect approaches:

  • Vacuum-Over-Liquid Transfer: A vacuum pump evacuates the collection vessel, drawing liquid into it through a pressure difference. Provide overflow protection and assess the effects of water vapor, aerosols, and condensate on the pump.
  • Pressure-Over-Liquid Transfer: A gas pump pressurizes the vessel containing the sample to push liquid out. The vessel must be pressure-rated, with appropriate valves and pressure control. Pressure may vary with system conditions, affecting flow consistency and accuracy.

Both methods keep the sample out of the pump, but tubing and valves must still be suitable for the liquid. For sampling with demanding flow accuracy requirements, compare these methods with direct transfer.

How should a pump be selected for stable liquid sampling flow or a specified volume per sample?

First determine whether the process requires continuous sample delivery or a specified volume per sample:

  • Continuous delivery: If the analyzer needs stable liquid sample flow, consider an intelligent liquid pump with Flow Control. Closed-loop control monitors and adjusts flow to maintain the setpoint as operating conditions change.
  • Specified-volume sampling: If each sample must have a preset shot volume, consider an intelligent dosing pump with Versatile Dosing, which focuses on precise, repeatable metering.

Provide the target flow or sample volume, sampling frequency, suction conditions, outlet back pressure, and sample properties to verify performance under actual operating conditions. Stable flow and accurate shot volume are different control objectives; select the pump and controls to suit the sampling process.

Please contact us for an assessment by DRF.