KNF FMS-FC 1.70 Intelligent Liquid Pump
Flow rate at atm. pressure
Up to 0.6 l/min
Pressure head
40 mWg
Suction height, self-priming
3 mWg
What are the main features and benefits of the KNF FMS-FC 1.70?

The FMS-FC 1.70 is an OEM diaphragm metering pump with closed-loop flow control. It delivers 0.18 – 0.6 l/min at atmospheric pressure, with a maximum pressure of 4 bar (gauge) and a maximum suction height of 3 mWg.

An integrated ultrasonic flow sensor feeds measurements to the controller, which adjusts motor speed to maintain the setpoint as backpressure or liquid temperature changes. Smooth Flow technology reduces pulsation, while configurable output parameters, fault and bubble detection, and flexible interfaces support equipment integration.

What intelligent features does the FMS-FC 1.70 provide?
Feature Function
Flow control An integrated PID controller regulates flow within the specified operating range as backpressure changes.
Temperature sensing Measured temperature is used to compensate for changes in fluid properties.
Bubble detection Three sensitivity levels allow detection to be adjusted for the fluid line.
Viscosity compensation Compensation uses the fluid viscosity entered in KNF Connect; it does not measure viscosity automatically. The standard setting range is 0.3 – 15 mPas, with 0.3 – 50 mPas available as a project option.

The flow setpoint can be supplied through the serial interface or analog/PWM input. Temperature and bubble information are available through the serial interface; corresponding analog/digital outputs require customization.

What are the accuracy and wetted-material specifications of the FMS-FC 1.70?

Setpoint accuracy is ±4% of reading with water, and specified repeatability is CV ±2%. Factory calibration uses water at 25°C and 0 bar (gauge); these values should not be assumed for every fluid or installation.

Permitted liquid temperature is 5 – 80°C, with an ambient range of 5 – 40°C.

Component Wetted material
Pump head PPS
Diaphragm PTFE-coated
Pump valves and O-rings FFKM
Sensor fluid channel PPS, PEEK
Sensor O-rings / fitting seals FKM

Note: The above specifications apply to the standard RT version. Additional material combinations are available and can be customized to meet project-specific requirements.

Which control signals and communication interfaces does the FMS-FC 1.70 support?
Parameter Specification
Connection 8-wire interface; Molex Micro-Fit 3.0 header
Nominal supply voltage (V) 24 ±10%
Power (W) 11.3
Maximum load current (A) 0.47
Control signal (V) 0 – 5
Control input Analog, PWM
Signal output PWM; analog or alternative output values on request
Serial interface UART TTL
Sensor/electronics housing protection IP40; IP54 on request

RS232 and CAN Bus are project options. KNF Connect and the appropriate USB starter-kit cable support configuration and initial testing.

The housing rating above applies to the sensor/electronics enclosure; the pump itself is rated IP30.

How do viscosity, pressure, and temperature affect flow in the FMS-FC 1.70?
Factor Effect and compensation
Viscosity 0.3 – 15 mPas at 20°C; default 1 mPas. Set the actual fluid viscosity in KNF Connect; higher viscosities require a project configuration.
Long-term drift Continuous flow feedback allows the controller to counter changes in pump delivery over time, within its operating capacity.
Pressure Closed-loop control compensates for changes within 0 – 4 bar (gauge), provided the operating point remains inside the specified flow/pressure envelope.
Temperature measurement Non-wetted measurement; accuracy ±5°C; response time t(90) = 3 min.
Liquid temperature Temperature feedback compensates for changes in fluid properties within the permitted operating range.
Suction height Specified flow influence: ±1% over 0 – 3 mWg.

Compensation depends on correct fluid settings and operation within the datasheet limits; it is not a guarantee of zero error under all conditions.

What fluid connections and tubing does the FMS-FC 1.70 require?
Fluid connection Specification
Sensor inlet 1 × DN4/6 compression fitting; PP body, FKM seal, G1/8 thread
Pump outlet 1 × DN4/6 compression fitting; PPS
Tubing size DN 4/6
Which OEM applications is the FMS-FC 1.70 suited to?

Typical applications include cleaning and disinfection equipment, medical diagnostics, industrial metering systems, laboratory instruments, inkjet printing, and chemical processing.

Closed-loop flow regulation helps these systems maintain liquid delivery as operating conditions change. Low-pulsation pumping and configurable control interfaces support integration into equipment that needs stable, precise metering.

Key Components & Customization Options
Pump Head PPS
Diaphragm PTFE-Coated
Valve and O-Rings FFKM
Sensor Fluid Channel PPS, PEEK
*Further combinations on request
Technical Details
Permissible ambient temperature +5° to +40°C
Permissible liquid temperature +5° to +80°C
Flow rate range at atmos. 0.8 – 1.6 l/min
Suction height 3 mWg
Set point accuracy ±4% reading with water
Calibration Calibration in factory @ 0 bar g / 25°C with water
Repeatability CV ±2%
Nominal pressure 40 mWg
Accessories & Spare Parts
Title Description Order No.
Starter-Kit cable USB – UART TTL USB Connecting cable to parametrize the FMS-FC System with the KNF Connect Software, open wire ends for power and control input/signal output 358825
Starter-Kit cable USB – RS232 USB Connecting cable to parametrize the FMS-FC System with the KNF Connect Software, open wire ends for power and control input/signal output 361323