KNF FD 1200 Diaphragm Liquid Pump
Flow rate at atm. pressure
Up to 0.065 l/min
Pressure head
60 mWg
Suction height, self-priming
4.5 mWg
Nominal stroke volume
50 – 200 μl
What is KNF “Versatile Dosing,” and how does it simplify mechanical design?

Featured in KNF’s next-generation Intelligent Pumps, “Versatile Dosing” replaces manual mechanical adjustments with electronic settings, reducing adjustment errors and simplifying pump integration.

  1. Electronic dosing control: Set dosing behavior through software without mechanical adjustments.
  2. On-the-fly adjustment: Change dosing parameters from shot to shot.
  3. Cavitation prevention: A stepper motor and actively controlled valves allow separate intake and discharge speeds to accommodate liquid viscosity and help prevent cavitation.
Which communication interfaces does the KNF FD 1.200 support, and how easy is it to integrate?

The FD 1.200 offers several control and installation options:

  • Serial communication: A 5-pin interface uses UART TTL as standard, with RS-232 and CAN bus available as project options. I²C availability requires project confirmation.
  • I/O control: A separate 12-pin interface handles digital and analog inputs and outputs independently of serial communication.
  • Faster development: A USB connection and PC GUI support parameter testing. Validated settings can be sent to KNF for a customized pump configuration.
  • Mechanical mounting: Three mounting fixture options provide installation flexibility.
What are the key performance and operating specifications of the FD 1.200?

The stepper motor supports partial strokes and adjustable stroke speed for precise dosing. A stiff diaphragm with rigid support helps maintain repeatability as pressure changes.

Parameter Specification Notes
Shot volume 50–200 µl For small-volume dosing
Maximum flow rate 40 ml/min in dosing mode
65 ml/min in priming mode
Maximum shot frequency: 3.33 shots/s
Setpoint accuracy / repeatability (CV) ±2% / ≤0.5% Factory calibration: water at 25 °C and 0 bar gauge
Maximum pressure head Outlet: 6 bar (85 psig)
Inlet: 2 bar (28.5 psig)
Dry suction height ≥4.5 mWg At a 200 µl shot volume
Electrical supply 24 VDC (±10%), 36 W Maximum load current: 1.5 A
IP protection IP20 as standard IP54 available on request
Which wetted materials are available for corrosive media in the FD 1.200?

The FD 1.200 has a PP housing and a chemically resistant PPS pump head. Two standard material variants cover different liquid compatibility needs:

Variant Application considerations Wetted elastomers and diaphragm
RP For liquids compatible with EPDM O-rings, diaphragm and valves: EPDM
RT For applications requiring PTFE and FFKM chemical resistance; compatibility also depends on the FKM O-rings O-rings: FKM
Diaphragm: PTFE
Valves: FFKM
What affects dosing accuracy in the FD 1.200?

The ±2% setpoint accuracy applies under factory calibration conditions. Suction height, outlet pressure, viscosity, temperature and operating time can affect the delivered volume:

Influence on accuracy RP RT
Suction height 0 / −2% per mWg 0 / −2% per mWg
Outlet pressure at 200 µl 0 / −0.2% per mWg 0 / −0.2% per mWg
Outlet pressure at 50 µl (minimum shot volume) 0 / −0.6% per mWg 0 / −0.6% per mWg
Liquid viscosity: 0.3–150 mPa·s 0 / −3% 0 / −5%
Liquid temperature: 5–80 °C ±2% ±2%
Ambient and liquid temperature: 5–50 °C ±3% ±3%
Drift at 200 µl after 54 million cycles ±4% ±4%
Drift at 50 µl after 54 million cycles* ±8% ±8%

*Primarily relevant to small target volumes of 50 µl.

What are the benefits of the actively actuated valves in the FD 1.200?

The actively actuated inlet and outlet valves in the FD 1.200 provide precise valve control for accurate dosing and flexible pump operation. Key benefits include:

  • Increased dosing precision
  • Bi-directional flow
  • Backflow-tight operation in both forward and reverse directions
What applications is the FD 1.200 suitable for?

The FD 1.200 is suited to medical diagnostics, laboratory automation and precision liquid dosing. Depending on liquid compatibility, applications also include food ingredient dosing, cleaning and disinfection, and industrial ink delivery.

Electronic dosing settings, adjustable intake and discharge speeds, and multiple control interfaces help engineers adapt the pump to their equipment.

Key Components & Customization Options
Pump Head Standard: PPS; PEEK available on request
Diaphragm EPDM / PTFE
Valves EPDM / FFKM
O-Rings EPDM / FKM
Housing PP
Motor Type Options DC
Technical Details
Flow rate 0.065 l/min at atm. pressure
Weight 0.7 kg
Shot volume range 50 – 200 μl
Max. shot frequency (shots per second) 3.33
Max. flow rate: dosing mode 40 ml/min
Max. flow rate: priming mode 65 ml/min
Set point accuracy ± 2% RD
Repeatability (CV) ≤ 0.5%
Calibration Calibration in factory @ 0 bar g / 25 °C with water
Suction height, dry ≥ 4.5 mWg @ 200 μl shot volume
Max. outlet pressure head 60 mWg
Max. inlet pressure head 20 mWg
Permissible media temperature +5° to +80°C
Max. media temp. for hot sterilization 95°C for max. 40 minutes
Permissible ambient temperature +5° to +50°C
IP protection factor IP20 (IP54 on request)
Operating voltage 24 ± 10% VDC
Power 36 W
I load max 1.5 A
Accessories & Spare Parts
Title Description Order No.
Starter-Kit cable USB – UART TTL USB Connecting cable to parametrize the FD 1.200 System with the KNF Connect Software, open wire ends for power 358830
Starter-Kit cable USB – RS-232 USB Connecting cable to parametrize the FD 1.200 System with the KNF Connect Software, open wire ends for power 365095
Filter: FS 60 T PVDF / FS 60 X PEEK KNF filters protect pumps and upstream equipment from particles, crystals and fibres; mesh opening: PVDF 70 μm, PEEK 35 μm PVDF: 346932 / PEEK: 323625
Contact Us Top

Selected Models