OEM Dosing/Metering Pumps
FMS-FC 1.400
- Flow rate at atm. pressure
- Up to 3.4 l/min
- Pressure head
- 60 mWg
- Suction height, self-priming
- 3 mWg
What intelligent features does the KNF FMS-FC 1.400 provide?
- Flow control: An integrated PID controller uses ultrasonic flow measurements to adjust pump speed as backpressure changes, keeping delivery within the specified operating range. Flow setpoints can be supplied through the serial interface or analog/digital input.
- Temperature sensing: Temperature feedback compensates for changes in fluid properties as the liquid warms or cools.
- Bubble detection: Three sensitivity levels allow detection to be matched to the fluid line.
- Viscosity compensation: Enter the fluid viscosity in KNF Connect within 0.3 – 50 mPas; the default is 1 mPas. Compensation uses this setting rather than measuring viscosity automatically.
What makes the FMS-FC 1.400 suitable for liquid metering?
- Stable delivery: Integrated Flow Control helps maintain consistent flow as pressure, liquid temperature, and pump performance change within the operating limits.
- Easy integration: Flexible communication interfaces and configurable outputs simplify connection to the equipment controller.
- Process monitoring: Fault and bubble detection help identify interruptions in liquid delivery.
- Chemical compatibility: Chemically resistant materials support a range of liquids, with material customization available for specific media.
What are the electrical specifications and communication interfaces of the FMS-FC 1.400?
| Parameter | Specification |
|---|---|
| Connection | 8-wire interface; Molex Micro-Fit 3.0 header |
| Nominal supply voltage (V) | 24 ±10% |
| Power (W) | 91 |
| Maximum load current (A) | 3.8 |
| Control signal (V) | 0 – 5; analog input also accepts a PWM signal |
| Signal output | PWM; analog or alternative output values on request |
| Serial interface | UART TTL |
| Sensor/electronics housing protection | IP40; IP54 on request |
How do viscosity, pressure, and temperature affect flow in the FMS-FC 1.400?
| Factor | Effect and compensation |
|---|---|
| Viscosity | 0.3 – 50 mPas at 20°C; default 1 mPas. Set the fluid viscosity in KNF Connect; higher viscosities require a project-specific configuration. |
| Long-term drift | Continuous flow feedback lets the controller counter changes in pump delivery over time, within its operating capacity. |
| Pressure | Closed-loop regulation compensates for pressure changes within 0 – 6 bar (gauge). The operating point must remain inside the datasheet flow/pressure envelope. |
| Temperature measurement | Non-wetted sensing; accuracy ±5°C; response time t(90) = 3 min. |
| Liquid temperature | Measured temperature supports compensation for changes in fluid properties. Permitted liquid temperature: 5 – 80°C; ambient temperature: 5 – 40°C. |
| Suction height | Specified flow influence: ±1% over 0 – 3 mWg. |
Compensation does not imply zero error under every operating condition. Setpoint accuracy is ±4% of reading with water, and specified repeatability is CV ±2%; factory calibration uses water at 25°C and 0 bar (gauge).
What fluid connections and tubing does the FMS-FC 1.400 require?
| Connection | Specification |
|---|---|
| Sensor inlet | 1 × DN10/14 compression fitting; PP body, FKM seal, G1/2 thread |
| Pump outlet | 1 × DN10/14 compression fitting; PP body, FKM seal, G3/8 thread |
| Tubing size | DN 10/14 |
Which applications is the FMS-FC 1.400 suited to?
- Medical and laboratory equipment: medical diagnostics and laboratory instruments.
- Industrial processes: liquid metering systems and chemical processing.
- Cleaning and printing: cleaning and disinfection equipment and inkjet systems.
FMS-FC 1.400 Features & Specifications
Technical Details
| Permissible ambient temperature | +5° to +40°C |
|---|---|
| Permissible liquid temperature | +5° to +80°C |
| Flow rate range at atmos | 0.8 – 3.4 l/min |
| Suction height | 3 mWg |
| Set point accuracy | ±4% reading with water |
| Calibration | Calibration in factory @ 0 bar g / 25°C with water |
| Repeatability CV | ±2% |
| Nominal pressure | 60 mWg |
Accessories & Spare Parts
| Title | Description | Order No. |
|---|---|---|
| StarterKit cable USB – UART TTL | USB Connecting cable to parametrize the FMS-FC System with the KNF Connect Software, open wire ends for power and control input/signal output | 358825 |