OEM Vacuum Pumps
Product Overview
Showing 12 of 12 products in this category
|
No. |
View |
Model |
Flow rate at atm. pressure l/min |
Vacuum mbar abs. |
Pressure bar g |
|
|---|---|---|---|---|---|---|
|
|
N 84.4 AN-Series |
4.8 |
2 |
0.3 |
||
|
|
N 84.3 AN-Series |
Up to
5 |
7 |
0.3 |
||
|
|
N 816.3 KPE |
16 |
15 |
0.5 |
||
|
|
N 920 AP-Series |
21 |
1.5 |
0.5 |
||
|
|
N 838 Series |
Up to
34 |
100 |
0.5 |
||
|
|
N 952 |
Up to
36 |
Down to
1.5 |
Up to
0.1 |
||
|
|
N 940.5 TTE |
48 |
2 |
0.5 |
||
|
|
N 940.5 AP-Series |
50 |
1.5 |
0.5 |
||
|
|
N 838.1.2 KN-Series |
Up to
60 |
Down to
90 |
0.5 |
||
|
|
N 860.3 ANE/ATE/FTE |
60 |
2 |
1 |
||
|
|
N 860.3 FTE |
60 |
2 |
1 |
||
|
|
N 880.3 AN.22E |
80 |
2 |
1 |
Note: Images are not to scale; for size comparison, please refer to the technical specifications or the actual product dimensions
OEM Vacuum Pumps Pump Selection FAQ
Why should pumping flow at the operating vacuum be checked when selecting a vacuum pump?
Ultimate vacuum is the lowest absolute pressure a pump can achieve; it does not directly describe pumping capacity during equipment operation. Confirm how much flow the pump can still deliver at the vacuum pressure required by the equipment.
Vacuum pump flow generally decreases as inlet absolute pressure falls, reaching zero at ultimate vacuum. Maximum flow rate and ultimate vacuum therefore represent different operating conditions.
Use the performance curve to verify available flow at the target vacuum. Also consider system volume, gas load, leakage, tubing restrictions, and whether continuous operation is permitted at that point. Ultimate vacuum alone cannot establish suitability for equipment requiring rapid evacuation.
When reading the performance curve, note that the horizontal axis of a vacuum curve shows inlet absolute pressure, measured with the outlet at 1000 mbar abs. (atmospheric pressure). A different actual outlet pressure changes performance. Curve values are also approximate, and actual performance may vary with test conditions and installation.
What is the difference between series and parallel vacuum pump configurations?
KNF multi-head vacuum pumps use different connections to meet requirements for higher pumping flow, deeper vacuum, or both:
- Parallel: The heads pump simultaneously, primarily to increase flow. With the same head design and operating conditions, ultimate vacuum generally remains similar. Two heads can have parallel inlets (increased inlet flow), parallel outlets (increased outlet flow), or both parallel inlets and outlets (increased flow on both sides). For evacuation applications, confirm the inlet connection arrangement.
- Series: Gas passes through the heads sequentially to provide multistage pumping, achieving lower absolute pressure and improving pumping performance at low absolute pressures. Flow does not increase directly with the number of heads.
- Combined series and parallel: Combines the flow advantage of parallel heads with multistage pumping in series for equipment requiring both pumping flow and deeper vacuum.
More pump heads do not necessarily mean higher flow. Check the actual connection arrangement and compare performance curves at the target operating vacuum.
Can a vacuum pump restart directly when the equipment is already under vacuum?
First confirm whether the selected model can start against vacuum. A vessel or line may retain vacuum after shutdown, so the pump must overcome the starting load with negative pressure already present at the inlet.
The ability to evacuate from atmospheric pressure does not guarantee restart under every vacuum condition. For repeated start-stop operation or equipment that retains vessel vacuum, provide the inlet absolute pressure, outlet pressure, and power supply conditions at restart to confirm a suitable pump and motor configuration.
Does adjusting vacuum pump speed maintain a stable vacuum?
Adjusting motor speed changes pumping performance, but constant speed does not mean constant vacuum. Vacuum pressure inside the equipment may change as the gas load or operating conditions change, even at the same speed.
KNF Vacuum Control combines a sensor with motor control to monitor vacuum and automatically adjust pump operation to maintain the setpoint. This closed-loop control is better suited than a speed setting alone to processes requiring stable vacuum under changing conditions.
Confirm the vacuum setpoint range, control requirements, and method of integration. Depending on configuration, pumps with Vacuum Control offer standalone operation, analog control, or digital communication to reduce the complexity of external control systems.
How can vacuum grippers balance rapid gripping with stability during movement?
Vacuum grippers and pick-and-place operations need to establish suction quickly and maintain reliable vacuum as the robotic arm moves. Assess pumping flow at the required operating vacuum, gripping time, and dynamic operating requirements as well as ultimate vacuum.
Pump location also affects equipment integration:
- At the robotic arm's end effector: Prioritize pump size and weight to avoid excessive payload, and match the available space at the gripper.
- At the robot base or another fixed location: Larger pump configurations may be considered for larger vacuum systems and pumping requirements.
KNF can adapt motors, eccentrics, connection configurations, and start-stop parameters to different pick-and-place cycles, vacuum release methods, and higher-level control systems. Match performance to the actual operating point, rather than simply choosing a larger pump or a lower ultimate vacuum.
Why is a deeper vacuum not always better for negative pressure control in inkjet printing?
Drop-on-Demand (DOD) printing uses controlled negative pressure to balance ink supply pressure and stabilize the ink meniscus at the nozzle. It requires an appropriate, stable negative pressure rather than the deepest possible vacuum.
- Insufficient negative pressure (meniscus pressure too high): May fail to balance ink supply pressure, allowing unintended dripping from the nozzle.
- Excessive negative pressure (meniscus pressure too low): May draw ink too far back into the nozzle, affecting replenishment and droplet formation and causing printing defects such as missing dots.
Pressure fluctuations of only about 3–5 mbar may reduce print quality. Selection should therefore prioritize the negative pressure setpoint and stability, rather than ultimate vacuum alone.
To assess a vacuum pump, please provide target operating vacuum, pumping flow, system volume, start-stop conditions, and control requirements. Contact us for selection assistance from DRF.