OEM Dosing/Metering Pumps

KNF Neuberger

KNF OEM dosing/metering pumps deliver highly precise flow control, maintaining linear and consistent dosing performance across varying pressures and operating conditions.

The portfolio includes Solenoid-Driven pumps and Stepper-Motor-Driven pumps, offering high repeatability, excellent flow adjustability, long service life and outstanding chemical resistance, backed by precision engineering and extensive customization capabilities.

Learn more

OEM Dosing/Metering Pumps Product Overview

Showing 10 of 10 products in this category

No.

View

Model

Flow rate at atm. pressure l/min

Pressure head mWg

Suction height, self-priming mWg

Nominal stroke volume μl

FEM 1.02.55 RC

FEM 1.02.55 RC

0.0002 – 0.02
l/min

60
mWg

4
mWg

5 – 180
µl

FEM 1.02

FEM 1.02

0.0002 – 0.02
l/min

60
mWg

4
mWg

180
µl

FEM 1.09.55 RC

FEM 1.09.55 RC

0.0009 – 0.09
l/min

60
mWg

4
mWg

10 – 500
µl

FEM 1.09

FEM 1.09

0.0009 – 0.09
l/min

60
mWg

4
mWg

500
μl

FMM 20

FMM 20

0.018
l/min

10
mWg

3
mWg

8 – 17
μl

FMM 80

FMM 80

0.048
l/min

10
mWg

4
mWg

30 – 80
μl

FD 1.200

FD 1.200

Up to 0.065
l/min

60
mWg

4.5
mWg

50 – 200
μl

FL 10

FL 10

0.1
l/min

10
mWg

1.5 – 2
mWg

--

FMS-FC 1.70

FMS-FC 1.70

Up to 0.6
l/min

40
mWg

3
mWg

--

FMS-FC 1.400

FMS-FC 1.400

Up to 3.4
l/min

60
mWg

3
mWg

--

Note: Images are not to scale; for size comparison, please refer to the technical specifications or the actual product dimensions

    OEM Dosing/Metering Pumps Pump Selection FAQ

    What liquid transfer applications are KNF OEM dosing/metering pumps suitable for?

    KNF OEM dosing pumps can be used in applications requiring precise liquid transfer, including inkjet printing systems, medical equipment, and food and beverage equipment.

    For example, the adjustable flow rate and linear control characteristics of the FM 50 make it suitable for equipment that adjusts liquid delivery in response to a control signal. It also offers self-priming, dry-running capability, and sealed liquid transfer. When selecting a pump, check the compatibility of the pump head, diaphragm, and valve materials with the liquid composition.

    Can KNF OEM dosing pumps maintain an accurate flow rate when back pressure changes?

    This depends on the pump model and operating range. For example, the manufacturer specifies a flow range of 0.1 – 0.5 l/min and setpoint accuracy of ±2% for the FM 50, and states that it retains linear flow characteristics at back pressures of up to 1 bar g.

    If the equipment needs to actively maintain a set flow rate, intelligent liquid pumps with Flow Control may also be considered. These models integrate sensing and motor control for applications requiring stable liquid delivery as conditions change. Actual performance must be confirmed for the selected model.

    Which signals can OEM equipment use to control dosing pumps?

    Control options vary depending on the pump and motor configuration.

    For supported models, the manufacturer can use two-point calibration at the factory to adjust the relationship between the control signal and flow rate within a defined range to meet equipment control requirements. Some intelligent models also offer communication interfaces such as UART for integration into OEM systems.

    How does motor parameter customization help with liquid dosing?

    For models that support parameter configuration, minimum and maximum speeds, acceleration and deceleration characteristics, and start/stop behavior can be preset to match the equipment’s operating sequence. Some motors can also provide information on speed, temperature, current, or fault status to support equipment monitoring and troubleshooting.

    Why do bubbles in the liquid affect dosing accuracy?

    Bubbles take up space in the pumping chamber, reducing the actual volume of liquid delivered. Both cavitation and the release of dissolved gases can reduce dosing accuracy, but they form in different ways: cavitation produces vapor bubbles when local pressure falls below the liquid’s vapor pressure, whereas gas release occurs when gases originally dissolved in the liquid form bubbles as pressure drops. These gas bubbles do not redissolve when pressure rises again.

    When designing the system, consider pressure losses caused by suction lines that are too narrow or too long, sharp bends, valves, and filters. The height of the liquid supply container, liquid temperature, and viscosity should also be considered to reduce the risk of cavitation.

    Which features of KNF OEM dosing pumps can be customized?

    Depending on the model, customization options include pump head, diaphragm, valve, and seal materials, as well as mounting arrangements, electrical connections, and liquid connections. Models that support digital configuration also allow parameters such as output setpoints, acceleration characteristics, and maximum speed to be adjusted.

    For example, a KNF Case Study describes a configuration with a PTFE-coated EPDM diaphragm, FFKM valves, FKM seals, and a PP pump head. The pump head was also rotated by 180° to accommodate the fluid and available equipment space.

    When discussing a customized solution, please provide as much information as possible about the liquid composition, required flow rate or dosing volume, suction conditions, back pressure, and control method. Please contact us to learn more about customized dosing pump solutions.

    Does KNF offer dosing pumps that can be operated directly in the laboratory?

    For laboratory benchtop use, reagent addition, or liquid dosing, consider KNF SIMDOS Laboratory Diaphragm Dosing Pumps. SIMDOS offers an intuitive user interface, programmable settings, and calibration functions, making it easy to set liquid delivery conditions to suit laboratory workflows.

    Back to Products Contact Us