KNF Laboratory Equipment
Lab Pump Finder
Categories
Diaphragm Vacuum Pumps and Compressors
KNF offers a complete line of diaphragm vacuum pumps and compressors for a variety of laboratory applications. Offering an excellent size/performance ratio, they are…
LIQUIPORT Diaphragm Liquid Transfer Pumps
Featuring high flow rates up to 3 l/min, splash-proof IP 65 and oil-free operation, KNF LIQUIPORT® diaphragm liquid pumps are self-priming, dry-run safe and…
Vacuum Controller
KNF VC 900 is a powerful, versatile vacuum control unit that easily integrates with nearly any diaphragm vacuum pump or house vacuum…
Chiller
The compact design, easy filling of the unit, and a membrane keyboard with water and splash proof make KNF Chiller C900 a perfect choice…
SIMDOS Laboratory Dosing/Metering Pumps
KNF SIMDOS series offers several programmable settings for lab dosing and metering, including a “cycle mode” for enhanced control. They are dry-run safe,…
Laboratory Vacuum Pump Systems
Vacuum pump systems from KNF are renowned for their rapid pumping speeds, strong end vacuum for shorter processing times, and the excellent compatibility with…
Rotary Evaporators
KNF rotary evaporators are designed to impress thanks to their distinct handling advantages, clever functional details, and well-thought-out safety…
Accessories
KNF offers a range of accessories such as pressure control valves and pulsation dampers to round off your fluid-handling…
KNF Laboratory Equipment Featured Products
Note: Images are not to scale; for size comparison, please refer to the technical specifications or the actual product dimensions
KNF Laboratory Equipment Pump Selection FAQs
Selecting a laboratory pump involves more than flow rate and ultimate vacuum. These FAQs highlight key application requirements and suitable KNF pumps and system configurations:
How should a pump for rotary evaporation or vacuum distillation be selected based on the solvent, operating temperature, and equipment capacity?
Rotary evaporation and vacuum distillation reduce pressure so that liquids can evaporate at lower temperatures. First determine the pressure required for the solvent at the intended operating temperature, then assess system capacity, vapor load, and vacuum control requirements.
Solvent and operating temperature: Different solvents have different vapor pressures and vacuum requirements. For heat-sensitive samples, assess the acceptable operating temperature together with the required pressure, rather than comparing only the deepest vacuum a pump can achieve.
Equipment capacity and vapor load: Insufficient flow can extend evacuation and evaporation times, while excessive pumping capacity can make control more difficult. Consider both the evaporation flask volume and the gas space of the entire system, as well as continuously generated vapor.
Actual operating point: Maximum flow rate is normally measured at atmospheric pressure, while ultimate vacuum is a separate performance endpoint. Check the performance curve to confirm sufficient pumping capacity at the required pressure.
Vacuum control and solvent recovery: Stable vacuum control helps the pump follow the evaporation process. A condenser condenses and recovers solvent vapor. Assess both requirements together.
KNF LABOPORT SC 820 G and LABOPORT SC 840 G integrate a vacuum controller, an inlet separator flask, and an outlet high-performance condenser for processes requiring vacuum control and solvent recovery. If a deeper vacuum is needed, also consider KNF N 920 G, which has an ultimate vacuum of 2 mbar abs., and select system components to suit the control and recovery requirements.
How can pump selection for gel drying and centrifugal concentration balance sample processing conditions with vapor removal?
Gel drying and centrifugal concentration both involve vacuum, heat, and the removal of water or solvents, but their selection priorities differ:
Gel drying: Match heating and vacuum conditions to the drying equipment and experimental method to reduce the risk of gel deformation or cracking. The aim is an appropriate, stable drying environment, rather than continuously pumping down to the pump’s ultimate vacuum.
Centrifugal concentration: Centrifugal force, vacuum, and heat are combined to process multiple small samples. Confirm the concentrator’s chamber capacity, solvent types, and vapor and condensate loads during processing.
Shared requirements: Include oil-free operation, compatibility of all media-contacting materials, and suitable vacuum adjustment or control in the assessment.
KNF LABOPORT N 820 G and LABOPORT N 840 G offer oil-free operation, chemical resistance, and manual speed control. Compare their pumping capacity against the equipment requirements. Manual speed adjustment changes pumping capacity; it does not automatically maintain a vacuum setpoint.
If condensate is likely to form inside the pump during centrifugal concentration, consider models with a Self-Drying System. Distinguish equipment chamber capacity from sample liquid volume when specifying the application.
How should chamber capacity, water vapor, and condensation be assessed for vacuum ovens and desiccation systems?
A vacuum oven uses heat and reduced pressure to promote evaporation of water or solvents. Desiccation focuses on removing moisture from solids or maintaining a dry environment for moisture-sensitive materials, often using a vacuum desiccator or drying chamber. Both require assessment of vessel capacity and target vacuum, but their vapor loads can differ considerably.
Chamber capacity: This affects initial evacuation time. For rapid evacuation of a large chamber, assess the corresponding pumping capacity.
Continuous vapor load: Heated drying can continuously release large quantities of water or solvent vapor. Do not select a pump solely on the evacuation requirements of an empty chamber.
Condensate handling: Determine whether vapor may condense in the tubing or pump head, and whether separator flasks, condensers, or a self-drying function are needed.
Materials and control: Confirm media compatibility, required operating pressure, and whether stable vacuum control is necessary.
KNF LABOPORT N 840.3 FT.40.18 is equipped with a Self-Drying System to help remove condensate from the pump heads while maintaining vacuum in the vessel. It is a candidate for processes where water vapor and condensation must be considered.
Chemical resistance and condensate handling are separate requirements. Solvent-resistant materials do not guarantee unchanged pumping performance when liquid condensate accumulates.
How should pumping capacity and vacuum be selected for vacuum filtration, solid phase extraction, and fluid aspiration?
Vacuum filtration, solid phase extraction (SPE), and fluid aspiration all use a pressure difference to move liquid. Select vacuum conditions according to the equipment and method used:
Vacuum filtration: Assess filter pore size, liquid viscosity, particle characteristics, collection flask capacity, and the number of funnels used simultaneously. Too little vacuum prolongs filtration; excessive vacuum may tear or collapse the filter medium.
Solid phase extraction: Match the SPE apparatus capacity and method requirements, including flow rate, vacuum adjustment, and the ability to handle solvent vapor and moisture.
Fluid aspiration: Confirm collection vessel capacity, liquid viscosity, and the number of aspiration points. In a typical arrangement, the vacuum pump evacuates the collection flask and the liquid collects inside it, rather than passing directly through the gas pump.
The compact KNF LABOPORT N 96 has a maximum flow rate of 7 l/min and can be considered for small filtration, SPE, or fluid aspiration systems. For multiple filtration units or aspiration points, compare the pumping capacity of KNF N 816.3 K_.18 Series or LABOPORT N 840 G.
The number of units used simultaneously is only an initial selection criterion. Filter resistance, tubing layout, and the operating requirements at each point must also be confirmed.
How do viscosity, vessel capacity, and target vacuum affect pump selection for liquid vacuum degassing?
Vacuum degassing lowers pressure to release dissolved gases from liquids. It is used in analytical sample preparation and in processing materials such as resins, gels, and creams. Suitable flow rate and vacuum depend on the media and system conditions.
Liquid viscosity: Gas escapes less readily from viscous media, so a deeper vacuum may be needed. Liquid volume alone is insufficient for pump selection.
Vessel and system capacity: Larger gas spaces require corresponding pumping capacity to establish vacuum within the expected time.
Target vacuum and operating point: Confirm the pressure required by the degassing method and the available flow at that pressure, rather than comparing ultimate vacuum alone.
Vapor and materials: Extracted gases may carry water or solvent vapor. Confirm material compatibility and the possibility of condensation.
KNF LABOPORT N 820 G provides oil-free operation, chemical resistance, and manual speed control. If the media and method require a deeper vacuum, compare KNF N 920 G. Final selection should reflect viscosity, vessel capacity, and target pressure.
Laboratory batch vacuum degassing and inline degassing within analytical instruments may require different system configurations. For integration into equipment such as HPLC systems, provide details of the degassing module and operating conditions separately.
Should LIQUIPORT or SIMDOS be selected for laboratory liquid transfer and dosing?
The distinction between liquid transfer and liquid dosing lies in whether a specified volume must be dispensed according to a setting, and in the accuracy and repeatability required.
Liquid transfer: Examples include moving a solution from a large container to a smaller one or transferring waste liquid to a collection vessel. Key factors include flow rate, wetted materials, self-priming capability, inlet and outlet conditions, and operating method.
Liquid dosing: In addition to transferring liquid, confirm shot volume, delivery rate, accuracy, repeatability, and programmed control requirements.
Pressure and control: Include any vacuum or pressure at the receiving vessel and any external signal control requirements in the selection.
The KNF LIQUIPORT series focuses on liquid transfer with adjustable flow, self-priming capability, and dry-running capability. The SIMDOS series offers dosing and metering functions. Start by comparing LIQUIPORT liquid transfer pump selection and SIMDOS dosing pump selection. Adjustable flow does not necessarily provide specified-volume dispensing. First determine whether the process requires continuous transfer or a specified volume per dispense.
What KNF LABOPORT vacuum pump and system configurations are available, and how should separator flasks, solvent recovery, and vacuum control guide selection?
KNF LABOPORT offers different configurations according to pumping performance, separator flask, solvent recovery, and vacuum control requirements:
| Configuration | Key Features | Selection Guidance |
|---|---|---|
| LABOPORT N 96 | Compact oil-free pump with manual speed control; PPS pump head, PTFE-coated diaphragm, and FKM valves | Small filtration, SPE, and fluid aspiration applications |
| LABOPORT N 820 G / N 840 G | Chemically resistant basic pumps with manual speed control and a gas ballast valve; compatible with system components | Select configuration according to pumping requirements and external accessories |
| LABOPORT SR 820 G / SR 840 G | Pump, base plate, and inlet and outlet separator flasks | Processes requiring separator flasks on both sides |
| LABOPORT SH 820 G / SH 840 G | Pump, base plate, inlet separator flask, and outlet high-performance condenser | Processes requiring condensation and recovery of solvent vapor |
| LABOPORT SC 820 G / SC 840 G | Pump, base plate, inlet separator flask, outlet high-performance condenser, and vacuum controller | Processes requiring both vacuum control and solvent recovery |
N 820 G and N 840 G can be expanded into systems using the corresponding components, but this expansion concept does not apply directly to N 96. The SR outlet separator flask is also different from the high-performance condenser in SH and SC systems. Select according to vapor handling and recovery requirements.
SC systems provide four operating modes with a touchscreen interface for setting and monitoring vacuum. The integrated ramp function automatically recognizes and tracks the boiling point without requiring a preselected solvent library.
How should pump materials and system configuration be checked when handling corrosive gases and solvent vapors?
Chemical resistance depends on compatibility between the media and every contacting component, including pump heads, diaphragms, valves, tubing, and seals. A chemical resistance designation does not establish suitability for every solvent.
Media conditions: Provide gas or solvent composition, concentration, temperature, and whether the media is a mixture.
Media-contacting materials: Confirm the complete material combination for the pump heads, diaphragms, and valves.
Vapor and condensate: Assess whether condensation may occur during operation and whether separation, condensation and recovery, or self-drying is required.
Overall configuration: Assess tubing, separator flasks, condensers, and other media-contacting components as well as the pump itself.
An inlet separator flask helps collect liquid entering the system, while an outlet condenser condenses and recovers solvent vapor. These components serve different functions and do not replace an assessment of the pump’s material compatibility. To discuss media and configuration, contact DRF for pump selection assistance.
Which KNF LABOPORT ATEX configurations are available for experiments involving flammable gases or solvent vapors?
KNF LABOPORT offers ATEX models with explosion protection for the internal pump atmosphere, which can be considered for experiments involving flammable gases or solvent vapors. Compare the following options according to pumping capacity, vacuum control, and solvent recovery requirements:
LABOPORT N 820 G / N 840 G: Suitable for combining with system components according to experimental requirements. The manufacturer’s ATEX marking is II 2/-G IIB+H2 T3.
LABOPORT SC 820 G / SC 840 G: Integrate a vacuum controller, inlet separator flask, and outlet high-performance condenser for processes requiring both vacuum control and solvent recovery. The manufacturer’s ATEX marking is II 3/-G Ex h IIB+H2 T3 Gc.
These ATEX markings apply to the internal atmosphere only. The markings for the basic pumps and complete systems differ, so confirm the configuration being purchased. If the installation site is also a hazardous area, suitability for the external atmosphere must be checked separately. Please contact us for selection assistance.