KNF FMS-FC 1.400 OEM Liquid Pump
Flow rate at atm. pressure
Up to 3.4 l/min
Pressure head
60 mWg
Suction height, self-priming
3 mWg
What intelligent features does the KNF FMS-FC 1.400 provide?
  • Flow control: An integrated PID controller uses ultrasonic flow measurements to adjust pump speed as backpressure changes, keeping delivery within the specified operating range. Flow setpoints can be supplied through the serial interface or analog/digital input.
  • Temperature sensing: Temperature feedback compensates for changes in fluid properties as the liquid warms or cools.
  • Bubble detection: Three sensitivity levels allow detection to be matched to the fluid line.
  • Viscosity compensation: Enter the fluid viscosity in KNF Connect within 0.3 – 50 mPas; the default is 1 mPas. Compensation uses this setting rather than measuring viscosity automatically.
What makes the FMS-FC 1.400 suitable for liquid metering?
  • Stable delivery: Integrated Flow Control helps maintain consistent flow as pressure, liquid temperature, and pump performance change within the operating limits.
  • Easy integration: Flexible communication interfaces and configurable outputs simplify connection to the equipment controller.
  • Process monitoring: Fault and bubble detection help identify interruptions in liquid delivery.
  • Chemical compatibility: Chemically resistant materials support a range of liquids, with material customization available for specific media.
What are the electrical specifications and communication interfaces of the FMS-FC 1.400?
Parameter Specification
Connection 8-wire interface; Molex Micro-Fit 3.0 header
Nominal supply voltage (V) 24 ±10%
Power (W) 91
Maximum load current (A) 3.8
Control signal (V) 0 – 5; analog input also accepts a PWM signal
Signal output PWM; analog or alternative output values on request
Serial interface UART TTL
Sensor/electronics housing protection IP40; IP54 on request
How do viscosity, pressure, and temperature affect flow in the FMS-FC 1.400?
Factor Effect and compensation
Viscosity 0.3 – 50 mPas at 20°C; default 1 mPas. Set the fluid viscosity in KNF Connect; higher viscosities require a project-specific configuration.
Long-term drift Continuous flow feedback lets the controller counter changes in pump delivery over time, within its operating capacity.
Pressure Closed-loop regulation compensates for pressure changes within 0 – 6 bar (gauge). The operating point must remain inside the datasheet flow/pressure envelope.
Temperature measurement Non-wetted sensing; accuracy ±5°C; response time t(90) = 3 min.
Liquid temperature Measured temperature supports compensation for changes in fluid properties. Permitted liquid temperature: 5 – 80°C; ambient temperature: 5 – 40°C.
Suction height Specified flow influence: ±1% over 0 – 3 mWg.

Compensation does not imply zero error under every operating condition. Setpoint accuracy is ±4% of reading with water, and specified repeatability is CV ±2%; factory calibration uses water at 25°C and 0 bar (gauge).

What fluid connections and tubing does the FMS-FC 1.400 require?
Connection Specification
Sensor inlet 1 × DN10/14 compression fitting; PP body, FKM seal, G1/2 thread
Pump outlet 1 × DN10/14 compression fitting; PP body, FKM seal, G3/8 thread
Tubing size DN 10/14
Which applications is the FMS-FC 1.400 suited to?
  • Medical and laboratory equipment: medical diagnostics and laboratory instruments.
  • Industrial processes: liquid metering systems and chemical processing.
  • Cleaning and printing: cleaning and disinfection equipment and inkjet systems.

 

Key Components & Customization Options
Pump Head PP
Diaphragm PTFE-Coated
Valve and O-Rings FFKM / FKM
Sensor Fluid Channel PPS
Sensor O-Rings & Fittings FKM
Technical Details
Permissible ambient temperature +5° to +40°C
Permissible liquid temperature +5° to +80°C
Flow rate range at atmos 0.8 – 3.4 l/min
Suction height 3 mWg
Set point accuracy ±4% reading with water
Calibration Calibration in factory @ 0 bar g / 25°C with water
Repeatability CV ±2%
Nominal pressure 60 mWg
Accessories & Spare Parts
Title Description Order No.
StarterKit cable USB – UART TTL USB Connecting cable to parametrize the FMS-FC System with the KNF Connect Software, open wire ends for power and control input/signal output 358825
Contact Us Top

Selected Models

KNF Customization · MOQ 1