OEM Dosing/Metering Pumps
FMS-FC 1.70
- Flow rate at atm. pressure
- Up to 0.6 l/min
- Pressure head
- 40 mWg
- Suction height, self-priming
- 3 mWg
What are the main features and benefits of the KNF FMS-FC 1.70?
The FMS-FC 1.70 is an OEM diaphragm metering pump with closed-loop flow control. It delivers 0.18 – 0.6 l/min at atmospheric pressure, with a maximum pressure of 4 bar (gauge) and a maximum suction height of 3 mWg.
An integrated ultrasonic flow sensor feeds measurements to the controller, which adjusts motor speed to maintain the setpoint as backpressure or liquid temperature changes. Smooth Flow technology reduces pulsation, while configurable output parameters, fault and bubble detection, and flexible interfaces support equipment integration.
What intelligent features does the FMS-FC 1.70 provide?
| Feature | Function |
|---|---|
| Flow control | An integrated PID controller regulates flow within the specified operating range as backpressure changes. |
| Temperature sensing | Measured temperature is used to compensate for changes in fluid properties. |
| Bubble detection | Three sensitivity levels allow detection to be adjusted for the fluid line. |
| Viscosity compensation | Compensation uses the fluid viscosity entered in KNF Connect; it does not measure viscosity automatically. The standard setting range is 0.3 – 15 mPas, with 0.3 – 50 mPas available as a project option. |
The flow setpoint can be supplied through the serial interface or analog/PWM input. Temperature and bubble information are available through the serial interface; corresponding analog/digital outputs require customization.
What are the accuracy and wetted-material specifications of the FMS-FC 1.70?
Setpoint accuracy is ±4% of reading with water, and specified repeatability is CV ±2%. Factory calibration uses water at 25°C and 0 bar (gauge); these values should not be assumed for every fluid or installation.
Permitted liquid temperature is 5 – 80°C, with an ambient range of 5 – 40°C.
| Component | Wetted material |
|---|---|
| Pump head | PPS |
| Diaphragm | PTFE-coated |
| Pump valves and O-rings | FFKM |
| Sensor fluid channel | PPS, PEEK |
| Sensor O-rings / fitting seals | FKM |
Note: The above specifications apply to the standard RT version. Additional material combinations are available and can be customized to meet project-specific requirements.
Which control signals and communication interfaces does the FMS-FC 1.70 support?
| Parameter | Specification |
|---|---|
| Connection | 8-wire interface; Molex Micro-Fit 3.0 header |
| Nominal supply voltage (V) | 24 ±10% |
| Power (W) | 11.3 |
| Maximum load current (A) | 0.47 |
| Control signal (V) | 0 – 5 |
| Control input | Analog, PWM |
| Signal output | PWM; analog or alternative output values on request |
| Serial interface | UART TTL |
| Sensor/electronics housing protection | IP40; IP54 on request |
RS232 and CAN Bus are project options. KNF Connect and the appropriate USB starter-kit cable support configuration and initial testing.
The housing rating above applies to the sensor/electronics enclosure; the pump itself is rated IP30.
How do viscosity, pressure, and temperature affect flow in the FMS-FC 1.70?
| Factor | Effect and compensation |
|---|---|
| Viscosity | 0.3 – 15 mPas at 20°C; default 1 mPas. Set the actual fluid viscosity in KNF Connect; higher viscosities require a project configuration. |
| Long-term drift | Continuous flow feedback allows the controller to counter changes in pump delivery over time, within its operating capacity. |
| Pressure | Closed-loop control compensates for changes within 0 – 4 bar (gauge), provided the operating point remains inside the specified flow/pressure envelope. |
| Temperature measurement | Non-wetted measurement; accuracy ±5°C; response time t(90) = 3 min. |
| Liquid temperature | Temperature feedback compensates for changes in fluid properties within the permitted operating range. |
| Suction height | Specified flow influence: ±1% over 0 – 3 mWg. |
Compensation depends on correct fluid settings and operation within the datasheet limits; it is not a guarantee of zero error under all conditions.
What fluid connections and tubing does the FMS-FC 1.70 require?
| Fluid connection | Specification |
|---|---|
| Sensor inlet | 1 × DN4/6 compression fitting; PP body, FKM seal, G1/8 thread |
| Pump outlet | 1 × DN4/6 compression fitting; PPS |
| Tubing size | DN 4/6 |
Which OEM applications is the FMS-FC 1.70 suited to?
Typical applications include cleaning and disinfection equipment, medical diagnostics, industrial metering systems, laboratory instruments, inkjet printing, and chemical processing.
Closed-loop flow regulation helps these systems maintain liquid delivery as operating conditions change. Low-pulsation pumping and configurable control interfaces support integration into equipment that needs stable, precise metering.
FMS-FC 1.70 Features & Specifications
Technical Details
| Permissible ambient temperature | +5° to +40°C |
|---|---|
| Permissible liquid temperature | +5° to +80°C |
| Flow rate range at atmos. | 0.8 – 1.6 l/min |
| Suction height | 3 mWg |
| Set point accuracy | ±4% reading with water |
| Calibration | Calibration in factory @ 0 bar g / 25°C with water |
| Repeatability CV | ±2% |
| Nominal pressure | 40 mWg |
Accessories & Spare Parts
| Title | Description | Order No. |
|---|---|---|
| Starter-Kit cable USB – UART TTL | USB Connecting cable to parametrize the FMS-FC System with the KNF Connect Software, open wire ends for power and control input/signal output | 358825 |
| Starter-Kit cable USB – RS232 | USB Connecting cable to parametrize the FMS-FC System with the KNF Connect Software, open wire ends for power and control input/signal output | 361323 |