KNF NVC 830.3 Micro Gas Pump
Flow rate at atm. pressure
Up to 2.6 l/min
Vacuum
55 mbar abs.
Pressure
0 bar g
What are the benefits of “Closed-Loop Vacuum Control” in the KNF NVC 830.3?

KNF developed “Closed-Loop Vacuum Control” to continuously monitor vacuum levels through integrated sensing and feedback and adjust pump operation accordingly. In the NVC 830.3, the system regulates pressure toward a defined setpoint, offering the following benefits for system integration:

  1. Pressure regulation: continuous monitoring allows the pump to correct deviations from the setpoint. The datasheet specifies sensor accuracy of ±15 mbar and drift of 1% per year; these are sensor specifications, not a guarantee of overall system control accuracy.
  2. Dynamic response: the controller adjusts pump operation when system pressure changes, helping stabilize the process within the pump’s operating limits.
  3. Demand-based operation: output adjusts to the vacuum demand, which can reduce unnecessary full-speed running and associated power consumption and noise.
  4. Simpler system design: integrated vacuum regulation can reduce the need for a separate controller or pressure switch dedicated to that function.
What are the key features and advantages of the NVC 830.3?

The NVC 830.3 combines a compact dual-head diaphragm pump with integrated vacuum control:

Feature Function and benefits
Closed-loop vacuum control Monitors vacuum and adjusts pump output to maintain the selected setpoint as system demand changes.
Digitally customizable motor BLDC control parameters and interface settings can be configured to match the customer’s OEM system requirements.
Compact performance Provides vacuum generation in a compact package, supporting integration into equipment with limited installation space.
Clean gas transfer Oil-free operation avoids lubricant contamination of the pumped gas.
Material and operating options
  • Materials: PPS pump head; standard EPDM diaphragm and valves. Diaphragm options are FKM / PTFE, while valve options are FKM / FFKM, available on request.
  • Temperature: standard ambient and media temperature range of 5°C – 40°C; an extended range is available on request.
  • Material compliance: FDA-approved material options are available. This does not constitute certification of the complete pump for a food or medical application.
What are the main performance and motor specifications of the NVC 830.3?
Specification 6 V version 12 V version 24 V version
Voltage (V) 6 12 24
Flow rate at atmospheric pressure (l/min) 1.2 2.4 2.6
Ultimate vacuum (mbar abs.) 55 55 55
Motor Integrated brushless DC, 2-wire / 4-wire / 5-wire configurations, 6 – 24 V
Imax (A) 0.70 0.75 0.55
Communication interface UART TTL, 3.3 V level (UART RS232, I2C or CAN Bus on request)
How many operating modes does the NVC 830.3 offer?
  • Mode 1: Fixed Set Point
    • Operation: the target vacuum is configured before delivery.
    • Application: suits equipment requiring one vacuum setpoint; the pump evacuates to that level and maintains it through closed-loop control.
  • Mode 2: Controllable Set Point
    • Operation: an analog input changes the vacuum setpoint. The datasheet’s 0 – 5 V mapping is an example: 1 V corresponds to -200 mbar gauge and 5 V to -1,000 mbar gauge.
    • Feedback: a PWM output reports the measured vacuum level to the host controller.

    The mapping illustrates the control signal settings; actual vacuum performance depends on the pump specifications and system conditions. The NVC 830.3 has a specified ultimate vacuum of 55 mbar absolute, which should be considered when selecting the target vacuum level.

  • Mode 3: Communicate
    • Operation: connects to an external controller through UART TTL serial communication.
    • Integration: supports real-time start/stop commands, multiple setpoints and PID parameter changes. Command libraries in several programming languages support integration into digitally controlled laboratory and semiconductor equipment.
What applications is the NVC 830.3 suitable for?

Oil-free gas transfer and integrated vacuum regulation support applications including:

  • Medical and laboratory equipment: analytical instruments, in vitro diagnostics and laboratory vacuum filtration.
  • Industrial equipment: semiconductor processes, inkjet printing and vacuum technology.
  • Food and beverage production equipment, with materials selected for the application.
  • Other applications: automotive systems, security and defense equipment, gas analysis and fuel cells.

Key Components & Customization Options
Pump Head PPS
Diaphragm EPDM (FKM or PTFE on request)
Valves EPDM (FKM or FFKM on request)
Motor Type Option Brushless DC
Technical Details
Flow rate 2.6 l/min at atm. pressure
Ultimate vacuum 55 mbar abs.
Permissible media temperature +5° to +40°C, extended temperature on request
Permissible ambient temperature +5° to +40°C, extended temperature on request
Weight 0.258 kg
Sensor accuracy / drift ± 15 mbar / 1% per year
Communication interface UART TTL 3.3V Level (UART RS232, I2C or CAN Bus on request)
Accessories & Spare Parts
Title Description Order No.
Spare Part Kit One kit per head containing valve and diaphragm. For a double-headed pump, two kits are required On request
Eccentric On request
Silencer 338498
Rubber-Bonded Metal On request
Serial Interface Adapter 347669
Filter 316422
Contact Us Top