OEM ATEX-Compliant Pumps

KNF Neuberger
ATEX Certified

Ex-proof pumps are designed to prevent internal or external explosions by enclosing parts that could ignite. KNF ATEX-compliant pumps are certified with the corrosponding EU Directive on equipment and protective systems.

Learn more

Showing 5 of 5 products in this category

No.

View

Model

Flow rate at atm. pressure l/min

Vacuum mbar abs.

Pressure bar g

N 87 TT.9E Ex

N 87 TT.9E Ex

7.5
l/min

140
mbar abs.

1.5
bar g

N 026 AT/ST.9E Ex

N 026 AT/ST.9E Ex

15
l/min

100
mbar abs.

2.5
bar g

N 026.1.2 AT/ST.9E Ex

N 026.1.2 AT/ST.9E Ex

26
l/min

100
mbar abs.

2
bar g

N 0150 AT/ST.9E Ex

N 0150 AT/ST.9E Ex

120
l/min

115
mbar abs.

1
bar g

N 0150.1.2 ST.9E Ex

N 0150.1.2 ST.9E Ex

220
l/min

115
mbar abs.

1
bar g

Note: Images are not to scale; for size comparison, please refer to the technical specifications or the actual product dimensions

    OEM ATEX-Compliant Pumps Pump Selection FAQ

    What information should be provided before selecting an ATEX explosion-proof gas pump?

    KNF ATEX explosion-proof pumps include Equipment Group II models in Categories 2G and 3G for gases, vapors, and mists. Selection requires confirmation of the media, hazardous area classification, and explosion protection requirements for both the internal and external atmospheres, in addition to flow rate, vacuum, and operating pressure.

    Wherever possible, provide gas composition, concentration, required flow rate, inlet and outlet pressures, media and ambient temperatures, and detailed information about the hazardous area classification at the installation site. These details help verify performance, material compatibility, and the suitability of the equipment category and temperature class.

    Selection must also establish whether the gas inside the pump or the external installation atmosphere presents a potential explosion risk. If only limited information is available, briefly describe the application and provide the media’s Safety Data Sheet (SDS), if available. Please contact us to clarify the requirements.

    How can suitability for the required potentially explosive atmosphere be confirmed?

    An “Ex” designation in the model name alone is insufficient. Check the full explosion protection marking in the manufacturer’s documentation, including equipment group, category, gas group, temperature class, and any special conditions of use. These must match the actual media and hazardous area requirements.

    KNF manuals explain how to interpret explosion protection markings, but markings and operating restrictions can vary between models. Verify the complete model and configuration; do not extend one model’s scope of use to every explosion-proof pump.

    Why must the internal and external atmospheres be checked separately?

    The pump’s internal atmosphere is the gas being transferred, while the external atmosphere surrounds the equipment at its installation site. They may present different explosion risks. Suitability for transferring a particular flammable gas does not establish suitability for installation in every hazardous area.

    Check the requirements for the media and surrounding atmosphere separately, and ensure the selected pump’s documentation covers the actual conditions of both. Also consider hazardous gas mixtures that could form following media leakage or component failure.

    Is an explosion-proof motor enough to make a gas pump ATEX suitable?

    Motor explosion protection alone does not establish the suitability of the complete pump. EU ATEX requirements address both the electric drive motor and the mechanical pump components. Potential ignition sources include friction, impact, electrostatic discharge, and hot surfaces as well as electrical sparks.

    KNF explosion-proof pump designs reduce ignition risks through suitable materials, conductive connections, and grounding measures. Select a complete explosion-protected configuration confirmed by the manufacturer, and install and operate it within the specified conditions.

    How should a pump be selected when a corrosive gas is also flammable?

    Verify material compatibility and explosion protection conditions together. Chemically resistant materials do not replace an explosion-protected configuration, and an explosion protection marking does not establish compatibility with every corrosive gas.

    Check the compatibility of diaphragms, valves, and all other media-contacting components as well as the pump head, and verify operating temperatures and pressures. Please provide the intended gas composition and application conditions and contact us to assess suitable materials and explosion protection configurations.

    What should be considered when installing and maintaining an ATEX explosion-proof gas pump?

    Follow the selected model’s manuals to check electrical connections, grounding, heat dissipation, and tubing layout, and leave adequate maintenance access. Ensure sufficient cooling air and ventilation, and regularly inspect the pump and gas connections for damage or leakage.

    Use original KNF parts and spares, and always contact DRF regarding repairs. Failure to follow the requirements may compromise the pump’s explosion protection and equipment safety. Please contact us for support.