- Flow rate at atm. pressure
- 0.5 l/min
- Pressure head
- 10 mWg
- Suction height, self-priming
- ≥ 3.0 mWg
What performance characteristics does the KNF FM 50 metering pump provide?
The FM 50 is designed for precise liquid metering, with a specified flow range of 100 – 500 ml/min at a 1 – 5 V control input. It provides a nominal pressure head of 10 mWg and a suction height of at least 3 mWg.
Its digitally customizable BLDC motor supports voltage or PWM control and a linear, predictable flow characteristic. Setpoint accuracy is ±2% and repeatability is CV 1% after factory two-point calibration with water at 25 °C.

What material and customization options are available for the FM 50?
| Material code | KP | KT | Details |
|---|---|---|---|
| Pump head | PP | PP | Chemically resistant standard pump-head material |
| Diaphragm | EPDM | PTFE | Select according to liquid compatibility |
| Valves | EPDM | FFKM | Select according to liquid compatibility |
| O-rings | EPDM | FKM | Select according to liquid compatibility |
Motor firmware and the two-point calibration curve can be configured for the OEM system. Pumps with the .51 code are NSF certified for food and consumable applications; FDA-approved material options are also available.
What original accessories and connection components are available for the FM 50?
| Item | Specification | Function |
|---|---|---|
| Mounting clip | Overhead mounting clip | Supports compact pump installation |
| Mounting plate | Universal mounting plate; 43 × 22 mm hole spacing; 3.5 mm sleeve ID | Mounting screws are included |
| Compression fitting | DN04/06; PP; FKM O-ring; G1/8 thread | For flexible tubing in higher-pressure applications |
| Hose connector | DN04; PP; FKM O-ring; G1/8 thread | Straight hose barb for lower-pressure applications |
| Filter | Available on request | Helps protect the pump and fluid circuit from particles, crystals and fibers |
FM 50 Features & Specifications
Technical Details
| Flow rate | 0.5 l/min at atm. pressure |
|---|---|
| Flow rate range | 0.1 – 0.5 (Vctrl 1 – 5 V) l/min |
| Set point accuracy | ±2%; KT Version requires a working pressure of > 0.7 mWg at 1 Vctrl to meet this specification |
| Calibration | Two-point calibration in factory @ 25°C, with water |
| Repeatability CV | 1% |
| Suction height | ≥3.0 mWg |
| Nominal pressure head | 10 mWg |
| IP protection factor pump | IP 30 |
| Permissible ambient temperature | +5° to +40°C |
| Permissible liquid temperature | +5° to +80°C |
| Drift over time (1000 hours) | ±4% |
| Drift over lifetime of 10,000 hours | ±6% |
| Liquid temp. between 5 – 80°C | KP Version: ±2%; KT Version: ±6% |
| Viscosity 1– 45 mPas | – 3% pro 15 mPas |
| Suction height between 0 – 3 mWg | 0 /- 4% |
| Pressure between 0 – 10 mWg | 0 /- 3% |
Accessories & Spare Parts
| Title | Description | Order No. |
|---|---|---|
| Mounting Clip Overhead | 351069 | |
| Clip for Side Mounting | 332358 | |
| Universal Mounting Plate | 164313 | |
| Filter | On request | |
| Compression Fitting | 175476 | |
| Hose Connector | 326642 |